20ft µEDC AI CDC Intelligent Monitoring System
Tier III
AI Mode
Total Cooling Capacity
165 kW
N+1 Redundancy Configuration
Current Load
84 kW
51% Utilization
Cold Aisle Temperature
20.5°C
Set: 18-22°C
Airflow Efficiency
98.2%
Excellent
System Overview
Cooling System
AI Intelligence
Maintenance Plan

🚀 System Status

• ✅ All systems running normally
• 🔄 Airflow circulation efficiency: 98.2%
• 📊 PUE: 1.28 (Excellent)
• 🛡️ Security Status: Normal

🏗️ Equipment Layout

• Rack A: 600mm deep (z=0.6m)
• In-Row CR060: 600mm deep (z=0m)
• Rack B: 600mm deep (z=-0.6m)
• RDHx×2: 170mm thick (Rack rear)
• Control Box: 1.1m×1.1m (Top right entrance)

❄️ Cooling System Status

• In-Row CR060: Running (60kW)
• RDHx A: Running (52.5kW)
• RDHx B: Running (52.5kW)
• Auxiliary Fan: Running (4000m³/h)

🌬️ Airflow Circulation System

🔴 Red Hot Air: Rack exhaust → RDHx cooling → Converges to In-Row center
🔵 Blue Cold Air: In-Row blows out → Cold aisle → Diverts to front of Rack A/B
🟢 Green Auxiliary: Fan pushes warm air from hot zone back to In-Row rear

🧠 AI Intelligent Features

Intelligent Temperature Prediction: Machine learning-based temperature trend analysis
Dynamic Fan Control: AI optimizes fan speed and energy consumption
Failure Prediction: Early detection of equipment anomalies
Energy Efficiency Optimization: Real-time PUE monitoring and optimization

📈 AI Performance Improvement

• Energy savings: 18.3%
• PUE improvement: 1.45 → 1.28
• Prediction accuracy: 94.7%
• Failure warning time: 2.5 hours in advance

🤖 AI CDC Real-time Processing

📊 Data Collection: Temperature, Humidity, Power, Airflow
🧠 Learning Mode: Analyzing Historical Data Patterns
🔍 Anomaly Detection: Identifying Abnormal Temperature Trends
Optimization Control: Adjusting Cooling Parameters
🔮 Prediction Analysis: 2-hour Temperature Forecast

🔧 Maintenance Plan

• Next maintenance: 30 days
• RDHx filter status: Good
• System runtime: 1,248 hours
• Maintenance history: No anomalies

📋 Maintenance Records

• 2024.10.01: Routine check - Normal
• 2024.09.15: Filter replacement - Complete
• 2024.08.20: System upgrade - Successful
• 2024.07.10: Preventive maintenance - Normal
DCIM Data Center Infrastructure Management
Environmental Monitoring
Power Monitoring
Equipment Management
Operations Management
Temperature Monitoring
Cold Aisle: 20.5°C | Hot Aisle: 28.3°C | Difference: 7.8°C
Humidity Monitoring
Current: 45% | Range: 40-60%
Airflow Efficiency
Current: 98.2% | Target: >95%
Leak Detection
Status: Normal | Last Check: 2 min ago
Smoke Detection
Status: Normal | Sensitivity: Medium
☀️ Clear
🌧️ Rain
❄️ Snow
⛈️ Storm
🌸 Spring
☀️ Summer
🍂 Autumn
⛄ Winter
UPS Status
Load: 42% | Battery: 100% | Runtime: 45 min
PDU Monitoring
Phase A: 28A | Phase B: 31A | Phase C: 26A | Total: 85A
Rack Power
Rack A: 12.3kW | Rack B: 11.8kW | Total: 24.1kW
PUE Efficiency
Current: 1.28 | Target: <1.30 | Monthly Best: 1.25
Power Cost
Today: $142 | This Month: $4,260 | Forecast: $4,800
Rack Space Utilization
Rack A: 14U/42U (33%) | Rack B: 16U/42U (38%)
Equipment List
Servers: 24 | Network: 6 | Storage: 4
Equipment Power Ranking
1. Compute Node A: 2.3kW | 2. Storage Array: 1.8kW
Network Connections
Connected: 28 | Available: 12 | Usage: 70%
Asset Value
Hardware: $285,000 | Software: $150,000 | Total: $435,000
Maintenance Schedule
Next: 30 days | Last: 15 days ago
SOP Execution
Today: 3/5 | This Week: 12/20
Alert Notifications
Today: 2 | This Week: 8 | This Month: 24
Capacity Planning
Power Headroom: 49% | Cooling Headroom: 52% | Space Headroom: 65%
Protocol Integration
SNMP: Normal | Modbus: Normal | BACnet: Normal | IPMI: Normal
Warning - Rack B temperature approaching limit (26.8°C)
Info - Routine maintenance scheduled in 3 days
Critical - UPS A battery needs replacement (capacity 78%)
🧠 AI CDC Intelligent Monitoring
System Status
Intelligent Optimization
AI Cooling Mode
Dynamic Optimization
Prediction Accuracy
94.7%
Energy Savings
18.3%
PUE Current
1.28
Failure Warning
0
✅ All systems normal, AI intelligent cooling optimization running

🤖 AI CDC Status

Learning Progress: 87%
Optimization Level: Advanced
Prediction Accuracy: 94.7%
Analysis Frequency: 10 times/sec
🎮 3D View Control
🌬️ Airflow Visualization
⚙️ Equipment Highlight
🤖 AI Control
🎯 Special Effects
🖱️ Wheel Zoom | 🎯 Drag Rotate | 💥 Double-click Reset
Area Legend
Hot Zone 0.3m
Cold Aisle 0.68m
Rack×2
In-Row
Auxiliary Fan×2
AI Sensors
```